The Varian PVD
Upgrades - ECS 3000 Control System
This upgrade comprises of a PC and touch screen together with a new Master Interconnect Chassis which replaces the now obsolete Fluke 1722A controller, Wafer Process controller, Wafer Loader controller, Ion gauge controller, Thermocouple gauge controller and Convectron gauge controller
The ECS software operates through a user friendly touch screen interface and can be Equipped with the SECS II interface to enable upload and download of data to a host computer
This upgrade significantly reduces the potential for electronic failures and at the same time brings the control system right up to date with on screen menu’s, history logging, maintenance functions and recipe control.
This upgrade requires a recipe controlled heater chassis, Varian Multigauge and later style Interlock and control chassis. These can be supplied if required.
The ECS can be configured to accept Quantum, Mini Quantum, Conmag I or Conmag II sources and can be interfaced with any of the sputtering power supplies used on Varian 3000 systems.
Target life is monitored and the user can set alarm and warning limits. Retrofit time is 3 days.
This upgrade cannot be fitted to 3280 systems and early systems having the 110 VAC utility box. (unless either the Varian 24 VDC or SMC utility box is retrofitted)
It should be noted that the multi pass option is not available within the ECS software.
 

Recipe controlled heater chassis - Eurotherm 808 digital temperature controllers for improved temperature stability
By using a Semicon Services Recipe Controlled Heater Chassis featuring Eurotherm 808 digital temperature controllers, you can help eliminate miss-processed wafers
Improved temperature stability, combined with automated temperature control ensures no process is started until every station is within the tolerances defined by your recipe.
This is available for three or four stations machines.
The heater chassis is connected with an RS422 serial link from your existing Fluke 1722.
If you currently have Fluke 1720’s, we offer an exchange program to allow you to upgrade to 1722’s

Shutter interlock chassis - Eliminates crescents on wafers by monitoring shutter position and creates an interlock in the event of jamming, sticking or slow shutter movement
The current design of the shutters on the 3000 series allows wafers to be processed when the shutters are jammed open or closed.
We have designed a retrofit, which monitors the position of the shutters, and in the event of an error, creates an interlock to prevent miss-processed or scrapped wafers. This is achieved by creating a “source out of regulation” interlock on the Fluke controller and can only be reset using a key switch on the front panel.
Three dual coloured LED’s identify the shutter at fault and an audible alarm will also sound.
Potentiometers on the internal PCB allow selection of time delay between 0.5 and 3.0 seconds before creating the interlock which allows for slow shutter movement when appropriate.
This upgrade also features counters which log shutter movements, and can only be reset using the keyswitch.
This assists in determining your preventative maintenance schedules, as well as target life, more accurately.
 

Remote con-mag monitor chassis - Predicts end of target life by accurately calculating KILOWATT HOURS. Pre-set KILOWATT HOUR values for alarm activation
This retrofit upgrade is designed to replace the remote Con-Mag meters which are fitted as standard to your Varian 3000 series
It will accurately monitor the voltage, current, kilowatts, and accumulated kilowatt hours of up to three installed targets.
This replaces the inaccurate meters which are subject to incorrect readings due to static electricity surface charging.
The Remote Con-Mag Monitor overcomes the historic difficulty in predicting end of target life by accurately counting elapsed kilowatt hours giving predictable target utilisation.
For inlayed targets such as platinum, the ability to accurately measure kilowatt hours removes the possibility of sputtering through the target material into the copper base.
Should you be sputtering precious metals such as gold, the ability to monitor actual usage of the target materials results in greater security and wafer cost management.
On reaching the end of target life, the operator is alerted by both audible and visual alarms.
In addition to this we offer the option of a process interlock.
These features are can only be reset by a keyswitch on the front panel

Wafer size conversion kits
Wafer size conversion kits are available for all 3000 systems. For the 3180/90 we offer 4” and 5” kits and for the 3290 4”,5” and 6” kits are available.
In addition 5” and 6” kits are available for the 3280. Both DC Bias and non DC Bias heaters can be supplied. It is recommended that a tool audit be carried out to establish the exact conversion kit requirements since this will depend on the options fitted
The kits can be installed by our Team of experienced Engineers thereby minimising the downtime on your tool.

SMC replacement pneumatic Utility Box
This replaces the existing mechanical utility box and can be retrofitted in place of both the 24 Volt DC Utility box and the early type 110 Volt AC utility box.
It eliminates the Humphrey, Alkon and Numatics valves replacing them with the latest type SMC valves.
Fitment of this box enables early systems to be upgraded with the ECS 3000 control system.